Heat Pump Repair in Warner Robins, GA
Homes here need heat from November through March and cooling from May through September. If your system quits, tell us what it's doing and a licensed contractor who covers Houston County will get in touch.
Tell us about the job
It takes about a minute.
Ten months of run time in Warner Robins
Your heat pump works from November through March to keep the house warm, then switches over and runs May through September to keep it cool. That's ten months a year with barely a break, and the system has to reverse itself between the two jobs. The reversing valve handles that switch, and it sees more cycles here than in a place with a short winter or a mild summer.
Summer afternoons averaging 91°F push the outdoor unit hard for hours at a time. Winter nights averaging 38°F mean it's still running most nights, just not as hard as somewhere colder. Most homes here heat with electricity, so when the heat pump can't keep up or won't start, there's no backup system quietly doing the job instead. Georgia households lost power for 24 hours or more often enough last year that it's worth knowing your heat pump won't restart on its own after an outage. Someone has to switch it back on.
- 5 months
- November through March, your system heats
- 5 months
- May through September, it cools
- 38°F
- the average winter night it heats against
- 91°F
- the average summer afternoon it cools against

NOAA nClimDiv, 1991–2020 normals
Georgia requires HVAC contractors to hold a state license.
The State Construction Industry Licensing Board tests contractors before they can hold this license. It also keeps a record of who holds one. The license belongs to the contractor, not to any single job. The same license that covers a new install covers this repair too.
A heat pump repair means someone is likely opening the refrigerant side of the system. Federal rule requires EPA Section 608 certification for that work, in Georgia and every other state. So on this job two things stand between you and a bad repair. One is the state license behind the contractor. The other is the federal certification behind whoever actually touches the refrigerant.
Source: Georgia Secretary of State
- Why is my heat pump blowing cold air?
- In heating mode, air from the vents is naturally cooler than your body temperature, so it can feel cold even when the system is working right. If it feels truly cold, not just cool, the problem is often the reversing valve stuck in the wrong position, or the system has lost refrigerant. A frozen outdoor unit will also cause this, since it cannot pull heat from the air. A contractor can check the reversing valve and refrigerant charge to find which one it is.
- Why is there ice on my heat pump?
- Some frost during a defrost cycle in winter is normal, but a heavy coating of ice that does not clear on its own is not. This usually means airflow across the outdoor coil is blocked, either by a dirty coil, a failed fan motor, or snow and debris around the unit. It can also mean the system is low on refrigerant, which drops the coil temperature below freezing. Since winter lows here average 38°F, the unit is already working in cold enough conditions that any airflow problem shows up fast. A contractor needs to check the defrost control, the fan, and the refrigerant level to find the cause.
- Why is my heat pump running but not cooling?
- The system running without cooling the house usually points to low refrigerant, a failing compressor, or a blocked outdoor coil that cannot release heat from the house. With summer afternoons here reaching 91°F, a heat pump that is even partly compromised will struggle to keep up, so the problem tends to show up quickly this time of year. Check that the outdoor unit has clear airflow around it and that the filter inside is not clogged, since both can look like bigger problems but are simple to rule out. If airflow is fine and the house still is not cooling, a contractor will need to check the refrigerant charge and the compressor.